mvHYPERION-HD-SDI is a frame grabber for high-definition cameras with SDI interface. Due to PCI Express® x4 the mvHYPERION-HD-SDI offers a peak capture bandwidth of 1 GB/s. The frame grabber allows operation of up to 2 independent HD-SDI cameras or 1 channel with 3G-SDI.
| Product | mvHYPERION-HD-SDI-2 |
|---|---|
| PCI Express® | x4 |
| Interfaces | 2 channels with HD-SDI standard or 1 channel with 3G-SDI on BNC connector RS485 interface for camera control, trilevel sync outputs, dig I/0 and camera supply on high density D-Sub connector |
| Continuous data rate | Approx. 620 MB/s |
| Peak data rate | 1 GB/s |
| Payload size | Up to 256 Bytes |
| Scan | Progressive |
| Permissible ambient temperature | 0 .. 45 °C |
| Permissible storage temperature | -20 .. 70 °C |
|
|
|
|
|
|
|
| Max. channels | Format | Frequency (fps) | Timing | Data |
|---|---|---|---|---|
| 2 | 1080p | 23.98, 24, 25, 29.97, 30 | SMPTE 274M (HD) | YUV 4:2:2 |
| 1 | 1080p | 50, 59.94, 60 | SMPTE 425M (3G) | YUV 4:2:2 |
| 2 | 720p | 23.98, 24, 25, 29.97, 30, 50, 59.94, 60 | SMPTE 292M (HD) | YUV 4:2:2 |
| Max. channels | Format | Frequency (fps) | Timing | Data |
|---|---|---|---|---|
| 2 | 1080p | 23.98, 24, 25, 29.97, 30 | SMPTE 274M (HD) | RAW10bit, RAW12bit |
| 2 | 1080p | 50, 59.94, 60 | SMPTE 425M (3G) | RAW10bit, RAW12bit |
| 2 | 720p | 23.98, 24, 25, 29.97, 30, 50, 59.94, 60 | SMPTE 292M (HD) | RAW10bit, RAW12bit |
| 2 | 720p | 100, 119.88, 120 | HD non-standard timing | YUV 4:2:2, RAW10bit, RAW12bit |
mvHYPERION-CLm/-CLf 64 Bit Windows (XP, Vista, 7)
Readme-Datei mit Installationshinweisen (mvIMPACT Acquire) / Readme file with installation guide (mvIMPACT Acquire)
Since version 1.10.69, the DirectShow® driver is part of the mvIMPACT Acquire installation package.
Since version 1.10.85, an interface to VisionPro® (Cognex) will be installed automatically when installing an MSI based mvIMPACT Acquire driver package.
mvIMPACT Acquire bindings for HALCON are available on MVTec's website: http://www.halcon.de/download/
32 Bit LabVIEW Binding ab Version 6.1 und größer / 32 Bit LabVIEW binding for LabVIEW 6.1 or greater
64 Bit LabVIEW Binding für alle x64 LabVIEW-Builds / 64 Bit LabVIEW binding for all x64 builds of LabVIEW
32 Bit LabView Binding History-Datei / 32 Bit LabView binding history file
To be able to watch or download the manuals, you have to be registered or logged in.
Subject to change without notice, Date 10/2011