CCD Sensor | 2448 x 2050 pixels (-x25)


   CCD 2448 x 2050 pixels (-x25)
      Details of operation
         Normal mode
         Fixed shutter
         One trigger
         Reset control
         VD Sync
         Input/Output signal
      CCD Sensor Data
         Characteristics
         Color version
         Gray scale version


CCD 2448 x 2050 pixels (-x25)

Details of operation

The process of getting an image from the CCD sensor can be separated into three different phases.

Normal mode

CCD_Normal.png

No. Description
1 0.32us to 19.57ms; approx. 4.78us/step (-S125C)
0.19us to 11.20ms; approx. 2.7us/step (-S125G)
2 4.78us to 19.57ms; approx. 4.78us/step (-S125C)
2.7us to 11.20ms; approx. 2.7us/step (-S125G)
3 Shutter time - strobe delay (when duration time is set to 0)

Fixed shutter

When external trigger signal is POSITIVE (high active), after the trigger signal rise, exposure is start. The exposure time is set by the camera electronic shutter speed. The video output is obtained immediately after the end of fixed exposure. The strobe signal start/end can be set to shutter time.

CCD_Fixed.png

No. Description
1 T1 = 1 / self frame rate [second]
2 3.73us to 19.57ms; approx. 4.78us/step (-S125C)
4.42us to 11.20ms; approx. 2.7us/step (-S125G)
3 0.24us to 19.57ms; approx. 4.78us/step (-S125C)
0.14us to 11.20ms; approx. 2.7us/step (-S125G)
4 4.78us to 19.57ms; approx. 4.78us/step (-S125C)
2.7us to 11.20ms; approx. 2.7us/step (-S125G)
5 Shutter time - strobe delay (when duration time is set to 0)

One trigger

When external trigger signal is POSITIVE (high active), after the trigger signal rise, exposure is start. At the trigger signal falling edge, the internal VD signal is reset and the video data are transmitted. The trigger signal width equals the exposure time.

CCD_One_Trigger.png

No. Description
1 T1 = 1 / self frame rate [second]
2 3.97us to 19.57ms; approx. 4.78us/step (-S125C)
4.23us to 11.20ms; approx. 2.7us/step (-S125G)
3 T2 = 56.0us + trigger delay (-S125C)
T2 = 30.6us + trigger delay (-S125G)
4 0.24us to 19.57ms; approx. 4.78us/step (-S125C)
0.14us to 11.20ms; approx. 2.7us/step (-S125G)
5 4.78us to 19.57ms; approx. 4.78us/step (-S125C)
2.7us to 11.20ms; approx. 2.7us/step (-S125G)
6 Shutter time - strobe delay (when duration time is set to 0)

The following trigger modes are available:

Mode Description
Continous Free running, no external trigger signal needed.
OnRisingEdge Each rising edge of trigger signal acquires one image.
OnHighExpose Each rising edge of trigger signal acquires one image, integration time corresponds to pulse width.

See also:
For detailed description about the trigger modes

Reset control

"When fixed shutter"

CCD_Reset_Control_1.png

No. Description
1 T1 = 1 / self frame rate [second]
2 3.73us to 19.57ms; approx. 4.78us/step (-S125C)
4.42us to 11.20ms; approx. 2.7us/step (-S125G)
3 0.24us to 19.57ms; approx. 4.78us/step (-S125C)
0.14us to 11.20ms; approx. 2.7us/step (-S125G)
4 4.78us to 19.57ms; approx. 4.78us/step (-S125C)
2.7us to 11.20ms; approx. 2.7us/step (-S125G)
5 108.7us to 19.68ms; approx. 4.78us/step (-S125C)
65.2us to 11.26ms; approx. 2.7us/step (-S125G)
6 Shutter time - strobe delay (when duration time is set to 0)

"When one trigger"

CCD_Reset_Control_2.png

No. Description
1 T1 = 1 / self frame rate [second]
2 4.78us to 19.57ms; approx. 4.78us/step (-S125C)
2.7us to 11.20ms; approx. 2.7us/step (-S125G)
3 T2 = 56.0us + trigger delay (-S125C)
T2 = 30.6us + trigger delay (-S125G)
4 0.24us to 19.57ms; approx. 4.78us/step (-S125C)
0.14us to 11.20ms; approx. 2.7us/step (-S125G)
5 4.78us to 19.57ms; approx. 4.78us/step (-S125C)
2.7us to 11.20ms; approx. 2.7us/step (-S125G)
6 Shutter time - strobe delay (when duration time is set to 0)
7 109.2us to 19.68ms; approx. 4.78us/step (-S125C)
65.6us to 11.26ms; approx. 2.7us/step (-S125G)

Special function of reset control mode

The camera shifts to the output of a normal mode (continuous output) when trigger input signal passes about 1/3 second in the state of High. It returns to the trigger mode if trigger input signal becomes Low. However, after becoming Low trigger input, the period of 50ms becomes a trigger signal input prohibition period.

CCD_Signal_Input_Prohibition.png

VD Sync

When external VD pulse is inputted, internal VD is reset. Exposure time is established shutter speed.

CCD_VD_Reset.png

No. Description
1 T1 = 4.21us (-S125C)
T1 = 4.19us (-S125G)

Note:
If the external VD of cycle which does not match the camera operation mode is input, shutter time has an error.

Input/Output signal

"Input signal"

The level of the trigger signal input to the camera is as follows.

High level +5.0 to +24V
Low level 0 to +0.3V
Threshold (Low -> High) +3.7 +/- 0.5V
Threshold (High -> Low) +3.3 +/- 0.5V

"Output signal" The level of the trigger signal output from the camera is as follows.

High level +5V
Low level 0V

CCD Sensor Data

Device Structure

Characteristics

These zone definitions apply to both the color and gray version of the sensor.

CCD24482.png

Color version

CCD24483.png

CCD24484.png

Gray scale version

CCD24485.png

CCD24486.png

CCD24487_1.png

CCD24487_2.png

CCD24487_3.png

CCD24487_4.png

CCD24487_5.png