Definizione telecamere

  • mvIMPACT Acquire
  • mvAcquireControl / mvSDK

copiare la definizione telecamera scaricata (file .xml) nella seguente directory:

  • Windows XP:
    C:\Documents and Settings\All Users\Documents\MATRIX VISION\mvIMPACT acquire\CameraFiles\
  • Windows Vista / 7:
    C:\Users\Public\Documents\MATRIX VISION\mvIMPACT acquire\CameraFiles\

Successivamente, lanciare wxPropView e selezionare la nuova definizione dal menù:
Setting -> Base -> Camera -> Type

CameraLink C-CAM FCi4-14000-B CameraLink C-CAM FCi4-14000-B | 1.8 kB

This camera description is valid for all bayer versions of the C-CAM FCi4-14000 area scan cameras. For 10 or 12 bit per tap operation change the BitsPerPixel parameter, for other tap configurations change the PixelsPerCycle parameter. Also you may need to configure the camera via serial communication.

CameraLink C-CAM FCi4-14000-M CameraLink C-CAM FCi4-14000-M | 1.7 kB

This camera description is valid for all mono versions of the C-CAM FCi4-14000 area scan cameras. For 10 or 12 bit per tap operation change the BitsPerPixel parameter, for other tap configurations change the PixelsPerCycle parameter. Also you may need to configure the camera via serial communication.

CameraLink DALSA P2-2x-01Kxx CameraLink DALSA P2-2x-01Kxx | 1.8 kB

This camera description is valid for all DALSA Piranha 2 line scan cameras with 1024 pixels hor. resolution and a 2 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P2-2x-02Kxx CameraLink DALSA P2-2x-02Kxx | 1.8 kB

This camera description is valid for all DALSA Piranha 2 line scan cameras with 2048 pixels hor. resolution and a 2 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P2-2x-04Kxx CameraLink DALSA P2-2x-04Kxx | 1.8 kB

This camera description is valid for all DALSA Piranha 2 line scan cameras with 4096 pixels hor. resolution and a 2 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P2-2x-06Kxx CameraLink DALSA P2-2x-06Kxx | 1.8 kB

his camera description is valid for all DALSA Piranha 2 line scan cameras with 6114 pixels hor. resolution and a 2 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P2-2x-08Kxx CameraLink DALSA P2-2x-08Kxx | 1.8 kB

This camera description is valid for all DALSA Piranha 2 line scan cameras with 8192 pixels hor. resolution and a 4 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P2-4x-04kxx CameraLink DALSA P2-4x-04kxx | 1.9 kB

This camera description is valid for all DALSA Piranha 2 line scan cameras with 4096 pixels hor. resolution and a 4 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P2-4x-06kxx CameraLink DALSA P2-4x-06kxx | 1.9 kB

This camera description is valid for all DALSA Piranha 2 line scan cameras with 6114 pixels hor. resolution and a 4 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P2-4x-08kxx CameraLink DALSA P2-4x-08kxx | 1.9 kB

This camera description is valid for all DALSA Piranha 2 line scan cameras with 8192 pixels hor. resolution and a 4 tap data output. The first x in the name can be anything between 0 and 3 and defines the lens mount option. The trailing xx defines the pixel clock per tap and can be 30 or 40. For 10 bit per tap operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA P3-8x-08k40 CameraLink DALSA P3-8x-08k40 | 1.9 kB

This camera description is valid for all DALSA Piranha 3 line scan cameras with 8192 pixels hor. resolution. The first x in the name can either be 0 or 7 and defines the shape of the cameras body. For 12 bit per tap operation change the BitsPerPixel parameter. Also you may need to configure the camera via serial communication.

CameraLink DALSA P3-8x-12k40 CameraLink DALSA P3-8x-12k40 | 1.9 kB

This camera description is valid for all DALSA Piranha 3 line scan cameras with 8192 pixels hor. resolution. The first x in the name can either be 0 or 7 and defines the shape of the cameras body. For 12 bit per tap operation change the BitsPerPixel parameter. Also you may need to configure the camera via serial communication.

CameraLink DALSA S2-1x-01kxx CameraLink DALSA S2-1x-01kxx | 1.8 kB

This camera description is valid for all single tap DALSA Spyder 2 line scan cameras with 1024 pixels hor. resolution. The first x in the name can be anything between 0 and 2 and defines the lens mount option. The trailing xx defines the pixel clock per tap and will be 40. For 10 bit operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA S2-1x-02kxx CameraLink DALSA S2-1x-02kxx | 1.8 kB

This camera description is valid for all single tap DALSA Spyder 2 line scan cameras with 2048 pixels hor. resolution. The first x in the name can be anything between 0 and 2 and defines the lens mount option. The trailing xx defines the pixel clock per tap and will be 40. For 10 bit operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink DALSA S2-1x-05hxx CameraLink DALSA S2-1x-05hxx | 1.8 kB

This camera description is valid for all single tap DALSA Spyder 2 line scan cameras with 512 pixels hor. resolution. The first x in the name can be anything between 0 and 2 and defines the lens mount option. The trailing xx defines the pixel clock per tap and will be 40. For 10 bit operation change the BitsPerPixel parameter and configure the camera via serial communication.

La vostra telecamera non è disponibile? Definite la vostra telecamera qui.

CAMDEFS CAMDEFS | 211.6 kB

Kameradefinitionen / Camera definitions