Definizione telecamere

  • mvIMPACT Acquire
  • mvAcquireControl / mvSDK

copiare la definizione telecamera scaricata (file .xml) nella seguente directory:

  • Windows XP:
    C:\Documents and Settings\All Users\Documents\MATRIX VISION\mvIMPACT acquire\CameraFiles\
  • Windows Vista / 7:
    C:\Users\Public\Documents\MATRIX VISION\mvIMPACT acquire\CameraFiles\

Successivamente, lanciare wxPropView e selezionare la nuova definizione dal menù:
Setting -> Base -> Camera -> Type

CameraLink Mikrotron Eosens-B CameraLink Mikrotron Eosens-B | 1.8 kB

This camera description is valid for all Bayer versions of the Mikrotron EoSens area scan cameras. For 8 or 10 bit per tap operation change the BitsPerPixel parameter, for other tap configurations change the PixelsPerCycle parameter. Also you may need to configure the camera via serial communication.

CameraLink Mikrotron Eosens-M CameraLink Mikrotron Eosens-M | 1.7 kB

This camera description is valid for all mono versions of the Mikrotron EoSens area scan cameras. For 8 or 10 bit per tap operation change the BitsPerPixel parameter, for other tap configurations change the PixelsPerCycle parameter. Also you may need to configure the camera via serial communication.

CameraLink Mikrotron MC1310 CameraLink Mikrotron MC1310 | 1.7 kB

This camera description is valid for all mono versions of the Mikrotron MC1310 area scan cameras. For 8 or 10 bit per tap operation change the BitsPerPixel parameter, for other tap configurations change the PixelsPerCycle parameter. Also you may need to configure the camera via serial communication.

CameraLink SENTECH CLC202A CameraLink SENTECH CLC202A | 1.5 kB

For 10 bit operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink SENTECH CLC33A CameraLink SENTECH CLC33A | 1.6 kB

This camera expects CC1=1. This can be achived by setting CC1s properties in the DigitalOutputs list (Mode = Manual, State = 0n)

CameraLink SENTECH CLC83 CameraLink SENTECH CLC83 | 1.6 kB

This camera expects CC1=1. This can be achived by setting CC1s properties in the DigitalOutputs list (Mode = Manual, State = 0n)

CameraLink SiliconImaging SI-1920HD CameraLink SiliconImaging SI-1920HD | 1.9 kB

This camera will always work with 12 bit internally but if you want to capture only the 8 or 10 MSB of the signal the BitsPerPixel parameter can be changed. The capture device(frame grabber) will skip the other bits then.

CameraLink Sony XCL-5000 CameraLink Sony XCL-5000 | 1.8 kB

This camera description is valid for all Sony XCL-5000 cameras. For 8, 10 or 12(default) bit mono operation change the BitsPerPixel parameter and configure the camera via serial communication.

CameraLink Sony XCL-5005 CameraLink Sony XCL-5005 | 2.3 kB

This camera description is valid for all Sony XCL-5005 and XCL-5005CR cameras. For 8, 10 or 12(default) bit mono(or RAW for color models) operation change the BitsPerPixel parameter and configure the camera via serial communication. For dual tap operation set the PixelsPerCycle parameter to 2 and configure the camera via serial communication. For color models set the Format parameter to Bayer to enable automatic color conversion inside the device driver OR set the BitsPerPixel parameter to 24 and the Format parameter to RGB and configure the camera via serial communication. In the latter mode the camera can deliver 8 bits per color component only.

La vostra telecamera non è disponibile? Definite la vostra telecamera qui.

CAMDEFS CAMDEFS | 211.6 kB

Kameradefinitionen / Camera definitions